DOWSIL 795 on wet or frosted surfaces

Wet joint? Clear out the water and frost before sealing, even with a sealant that cures with moisture.

Hold off on DOWSIL 795 if the surfaces you're bonding are still wet or covered in frost. Dow lists wet and frosted surfaces under the product's limitations. Its joint preparation instructions call for removing both water and frost before you apply the sealant.

How long should you wait after rain or frost removal? The sheet doesn't give a drying time, so don't guess one. It also doesn't explain the specific failure mechanism behind the restriction, though the restriction itself is clear.

Why moisture cure doesn't mean wet-surface application

Atmospheric moisture is what cures DOWSIL 795. But you still can't apply it to wet or frosted surfaces. The cure process doesn't remove that separate restriction.

Rain and snow resistance fall under weatherability in Dow's sheet. You can't take those listings as permission to gun a fresh bead onto a wet joint.

Before you start the bead

Before you run the bead, inspect the surfaces it'll bond to. Dow's preparation instructions call for removing grease, oil, dust, water, frost, surface dirt, old sealant or glazing compound, and protective coatings.

Check the joint again before you start. Water left after clearing frost still puts it under the wet-surface restriction, no matter how long it's been since you cleared it.

Don't treat primer as a way around the wet- or frosted-surface restriction. Dow's sheet says nonporous surfaces generally don't need primer, while certain porous surfaces may need it. Either way, Dow always recommends a test placement.

A cold day needs more than an air-temperature check

Above 50°C at the surface? Dow excludes installation. The sheet also lists all-temperature gunnability, but you still have to follow its surface restrictions.

For detailed application methods and joint design, go to the Dow Americas Technical Manual, Form No. 62-1112, as Dow directs installers to do. The supplied sheet doesn't give you a minimum installation temperature, a moisture-content threshold or a set drying interval after frost removal. Its weatherability temperature range isn't an installation range.

If the joint won't stay dry

Before you proceed with DOWSIL 795, get application advice and keep the application on hold. Include the joint detail and substrate names in your request, along with the surface temperature and a description of any water or frost.

Buying for a cold-weather job? Settle the installation conditions before you decide what to order. You'll find product details on the DOWSIL 795 product page.

Related comparisons and guides