Sealing porous substrates around a window
A primerless description doesn’t replace an adhesion test. Check the bond on the materials you’ll use for the job.
For a window perimeter against stucco, masonry or concrete, you can consider TremGlaze U1500, an exterior polyurethane sealant that typically bonds without primer. Damp, green or contaminated surfaces are off limits. Before you apply it, Tremco recommends a field adhesion test on the actual job materials to confirm the surface preparation and find out whether primer is needed.
Check both sides of the joint
Check both sides of the joint: the masonry opening and the metal or plastic window frame. Does either side need primer? The U1500 sheet lists Vulkem Primer #191 Low VOC QD for porous substrates and TREMprime Non-Porous Primer for metals and plastics.
A primerless description alone won’t settle the choice for your opening. Before you order, record both surfaces, any coatings and the joint dimensions, then ask for the field adhesion test in ASTM C1193, Appendix X1. That’s the test Tremco references for checking the actual job materials.
Get back to a sound, clean surface
Start with what needs removing. Release agents, existing waterproofing, dust, loose mortar, paint, other finishes and field-applied coatings all have to come off so the surfaces underneath are sound and clean, as Tremco calls for. Match the preparation method to the contamination. The sheet lists wire brushing, grinding, sandblasting or solvent washing.
Applying U1500 below 5°C? Consult Tremco’s cold-conditions bulletin, S-08-44 rev 1, for the procedure, because the sheet alone doesn’t cover the full cold-weather process. Tremco recommends a surface temperature of 5°C or above, so check it before you apply the sealant.
Leave room for the bead to work
For a window fillet or angle bead, leave at least 6 mm of contact between U1500 and each substrate. At the heel of the bead, use backer rod or bond breaker tape so the sealant can release there.
For joints that need backing, the sheet recommends closed-cell or reticulated polyethylene backer rod to control sealant depth. Keep it dry during application. If the joint’s too shallow for rod, use the adhesive-backed polyethylene bond breaker tape called for in the sheet to prevent three-sided adhesion.
Friction-fit the rod first. Apply any needed primer next, then fill the joint and tool the bead so the sealant contacts the joint walls. Dry tooling is Tremco’s preference.
Keep the exterior and cure limits in view
Keep U1500 outside. The sheet expressly bars use inside an occupied building, even if everyone leaves while you apply it. For ventilation, protective equipment and health precautions, read and follow the SDS.
Tremco gives a general cure rate of 2 mm per day at 24°C and 50% relative humidity. Lower temperature or humidity means a longer cure. For a colder opening, don’t use that general rate to lock in a completion date.
U1500 is paintable, but the sheet doesn’t promise that every paint will adhere or be compatible. Planning the paint work? Read Tremco bulletin S-09-05 first, as the sheet directs.
Take the opening details to the product check
Before you order, open the TremGlaze U1500 product page with your job details in hand: substrate names, coatings, joint width and depth, and expected application conditions. If you’re still unsure, send those details to Cranco. Ask what you need for surface preparation, adhesion testing and primer confirmation.