Does DOWSIL 790’s no-stain result cover your stone?

Use the reported result to assess the sealant, then check your project's stone and joint details.

Dow’s DOWSIL 790 technical sheet reports “None” for staining on various substrates under ASTM C1248. That supports considering it for natural-stone joints, but it doesn’t establish a no-stain result for your particular stone. The supplied sheet doesn’t name the tested substrates or give individual test results.

Dow also describes DOWSIL 790 as low-staining, plasticizer free and suitable for porous substrates, and lists joints between natural stone among its applications. Those statements support the intended use. They aren’t a promise that every stone will stay unmarked.

What you can put in the submittal

Keep the product, test and result together: DOWSIL 790 Silicone Building Sealant; ASTM C1248; staining on various substrates; reported result “None”. Dow places that result in its typical-properties table.

Need confirmation for a specific limestone or marble? This sheet alone won’t settle it. It provides no stone names, finishes, specimen details or separate staining results to match against your order. Don’t turn “various substrates” into “all natural stone”.

Before you commit the stone order

1. Record the exact stone, finish and any surface treatment. Give the sealant manufacturer those details along with the proposed DOWSIL 790 colour and joint location.

2. Ask for a staining assessment that covers your proposed materials. If a project-specific test is needed, agree on the samples, preparation, test method and acceptance criteria with the manufacturer and project specifier before work starts.

3. Keep the written assessment with the submittal. If all you have is the general data sheet, describe it that way rather than calling your stone tested or approved.

A staining result doesn’t settle the whole joint

Check adhesion and permitted use separately. Dow lists unprimed adhesion to natural stone, masonry and concrete as a product benefit, but that is a separate statement from the ASTM C1248 staining result.

The sheet also excludes structural applications, continuous water immersion and surfaces that will be painted after application. A favourable staining result doesn’t remove those restrictions.

Open the DOWSIL 790 product details for the product enquiry. Include your stone details and ask whether supporting staining information is available for that exact material.

Related comparisons and guides